155 Tooley Street – Motorised Smoke and Fire Damper (MSFD) Installation

Alpha Controls project managed and delivered a complete motorised smoke and fire damper (MSFD) installation at 155 Tooley Street — a life-safety package spanning every floor from lower ground to Level 4 and the basement plant room. The scope covered new secondary containment, FP200 fire-rated power and network cabling, red MSFD connection boxes at every damper, and three dedicated control panels, delivered to a tight programme alongside the building's wider BMS works.

Tooley Street, London SE1
2026
Commercial Office
155 Tooley Street MSFD Installation

Project Overview

At 155 Tooley Street, an eight-storey commercial office in London Bridge, Alpha Controls was responsible for the building's motorised smoke and fire damper (MSFD) system — a critical life-safety package controlling smoke and fire spread through the risers and floor distribution. Alpha Controls managed the MSFD scope from start to finish, taking full ownership of containment, fire-rated cabling, damper terminations, panel installation, and commissioning support.

Working across all levels from lower ground to Level 4 and the basement plant areas, Alpha Controls coordinated closely with the mechanical contractor and other trades on site, and provided additional support to the mechanical contractor on their Building Management System installation to keep the wider programme on track.

Basement riser cable tray and containment at 155 Tooley Street
Galvanised conduit riser feeding a red MSFD connection box at 155 Tooley Street

Secondary Containment

A core part of the package was establishing dedicated, fire-integrity containment for the life-safety cabling. Alpha Controls installed new secondary containment throughout the building:

  • Riser Containment: New cable tray, trunking and unistrut bracketry installed within the risers to carry MSFD power and network cabling vertically through the structure
  • Basement Distribution: Containment routed from all primary CMS in the basement, including tray and conduit feeding the plant room, to support the onward distribution of fire-rated cabling
  • Segregation: Life-safety cabling kept on its own dedicated containment and clearly separated from other services to protect circuit integrity

FP200 Fire-Rated Cabling

All MSFD power and signal cabling was installed in FP200 fire-rated cable, selected for its fire-resistant performance on life-safety circuits:

  • 24V Power: FP200 runs delivering 24V power to every motorised smoke and fire damper across the building
  • Network Cabling: A fire-rated network chain linking the dampers floor-by-floor and back to the control panels
  • Red Connection Boxes: A dedicated red MSFD connection box installed at each damper, with cabling terminated to the damper PCB
  • Routing Back to Panels: All circuits dressed and routed through the new containment back to the three MSFD panels in the basement plant room
FP200 fire-rated cabling on new containment
Red MSFD connection boxes terminated to damper PCBs

MSFD Control Panels

Alpha Controls installed three MSFD control panels within the basement plant room, mounted together on unistrut alongside the building's existing BMS panel so that header trunking could span the full panel line-up. Siting all three panels together gave a single, accessible control point for the building's motorised smoke and fire dampers, simplifying both commissioning and long-term maintenance.

Alpha Controls also supported the network commissioning of the damper system, assisting the commissioning engineer with fault-finding so the network could register and address the dampers across all floors.

Three MSFD control panels and the BMS panel in the basement plant room

BMS Support for the Mechanical Contractor

In parallel with the MSFD works, Alpha Controls assisted the mechanical contractor with their BMS installation, pulling cabling and installing containment across the building. This support package included containment and cabling for:

  • CAV & VAV Units: Constant and variable air volume terminals
  • MVHR Units: Mechanical ventilation with heat recovery
  • Heater Batteries
  • Washroom & Waste Pumps
  • DALI Lighting Interface
  • Electrical & Water Metering
  • Secondary Containment to carry the BMS field cabling

This collaborative approach kept the life-safety and BMS packages progressing side by side and helped hold the overall site programme.

Project Management with GUVNR.ai

Alpha Controls project managed the MSFD installation from start to finish, holding a tight programme across the full duration of the works. The job involved ongoing design changes throughout the installation — including revised damper positions and additional dampers added late in the programme — which Alpha Controls absorbed without losing schedule.

Operative planning and shift tracking were managed using GUVNR.ai, the workforce management platform that gave Alpha Controls live visibility of who was on site, what was completed each shift, and what remained. That visibility made it possible to react quickly to design changes, scale the team up on key days, and keep the right people on site at the right time throughout.

Actionair 24V motorised smoke and fire damper actuator wired at 155 Tooley Street

Results

The completed MSFD installation at 155 Tooley Street delivers:

  • A Complete Life-Safety Damper System: Motorised smoke and fire dampers across every floor, powered and networked back to dedicated control panels
  • Dedicated Fire-Rated Infrastructure: FP200 cabling on new secondary containment throughout the risers and basement
  • Centralised Control: Three MSFD panels grouped in the basement plant room for accessible control and maintenance
  • Programme Held Through Change: A tight schedule maintained despite ongoing design changes, supported by GUVNR.ai workforce planning
  • Multi-Trade Coordination: MSFD works delivered alongside support for the mechanical contractor's BMS installation

Technical Specifications

Life-Safety System

  • Motorised Smoke & Fire Dampers (MSFD)
  • 3× MSFD Control Panels
  • Red MSFD Connection Boxes (per damper)
  • Basement Plant Room Location

Cabling & Containment

  • FP200 Fire-Rated Cable
  • 24V Damper Power Circuits
  • Fire-Rated Network Chain
  • Secondary Containment (Risers & Basement)

BMS Support

  • CAV / VAV Cabling
  • MVHR, Heater Batteries, Pumps
  • DALI Lighting Interface
  • Electrical & Water Metering

Project Delivery

  • Full Project Management
  • Design-Change Management
  • GUVNR.ai Shift Planning & Tracking
  • Tight Programme Delivery