BMS & Energy Optimisation for FM Projects
We work with facilities management teams to deliver complete BMS and energy optimisation projects — from BMS installation in Kent and London to legacy system upgrades and ongoing maintenance.
Recent Projects
BMS installations and electrical engineering projects across the UK.

AstraZeneca Campus – Pancras Square
Accredited & Trusted
Industry-recognised certifications for your peace of mind




What Our Clients Say
“Alpha Controls carried out a full BMS upgrade at our site in 53/54 Grosvenor Street London — new Trend IQ4E controllers, network cabling, and commissioning. From the initial survey through to handover, Darren and the team were professional, knowledgeable, and easy to work with. What stood out was the communication, we always knew what was happening and when.”
“Had Alpha Controls in at our building on Whitechapel to carry out controls and electrical work. Really impressed with the whole process, the team knew exactly what they were doing, turned up when they said they would, and kept us informed throughout. The quality of the installation was spot on and everything was tested and commissioned properly before handover. No snagging, no call-backs, just done right first time.”

Projects Delivered at CBRE, JLL & Savills Managed Buildings
Led by experienced building controls and electrical engineers, Alpha Controls is a trusted BMS specialist, delivering energy-efficient control solutions for FM and M&E projects across London, Kent and the South East.
Expert Engineers
Fully qualified and certified engineers with extensive experience in BMS and controls
Quality Assured
SafeContractor approved, BCIA member, ECS certified, and Red Cross first aid trained
Nationwide Coverage
Serving clients across the UK with prompt, professional service
24/7 Support
Round-the-clock emergency support and maintenance services available
- Control point specifications
- Network architecture guidelines
- Commissioning checklists
No spam. Unsubscribe anytime.
Frequently Asked Questions
Why is one side of my office always too hot while the other side is freezing?
This is usually caused by poor zoning in the BMS, stuck or failed damper actuators, miscalibrated temperature sensors, or solar gain. Alpha Controls carries out thermal surveys and BMS audits to identify the root cause, then reconfigures zones and adjusts control strategies.
Why are my energy bills so high even though we have a BMS?
Many BMS systems are commissioned once and never tuned again, so they keep running default schedules long after the building's occupancy and use have changed. Alpha Controls carries out energy audits and BMS optimisation — reviewing schedules, setpoints and control sequences against how the building is actually used — and reports the saving measured against your own metered baseline rather than a headline percentage.
Our commercial property has a low EPC rating — can BMS controls help us improve it?
Yes. Upgrading BMS and HVAC controls is a recognised measure for improving EPC ratings. Since April 2023 it has been illegal to let commercial property below Band E, with Band C required by 2027 and Band B by 2030. Alpha Controls helps meet MEES compliance deadlines through BMS upgrades.
Our Trend 963 supervisor has reached end of life — what are our options?
As of January 2025, Trend has withdrawn all support for the 963 Supervisor. The recommended upgrade path is to Trend IQVISION, built on Niagara 4 with HTML5 browser access. Alpha Controls carries out 963 to IQVISION migrations, preserving existing IQ controllers where possible.
How long does a BMS installation take?
A small office fit-out with 20-30 fan coil units might take 2-4 weeks. A multi-floor commercial building with AHUs, chillers, boilers, and metering could take 8-16 weeks. Alpha Controls provides detailed programmes and works around tenant occupation.
What happens if our BMS goes down completely?
A complete BMS failure means loss of automated HVAC control, wasting energy or causing shutdowns. Alpha Controls provides emergency same-day callout services across London and the South East, plus resilience improvements including controller redundancy and cloud monitoring.
Can you take over maintenance of a BMS installed by another company?
Yes. Alpha Controls regularly takes over maintenance of Trend, Honeywell, and Distech systems installed by other contractors, providing full support including software changes, hardware replacements, and system extensions.
Our building has a proprietary BMS that only one company can service — can we escape this lock-in?
Yes. Alpha Controls specialises in migrating proprietary systems to open-protocol platforms using BACnet, Modbus, or LON, giving you freedom to choose your maintenance provider and integrate equipment from any manufacturer.
How much energy could we save by upgrading our BMS controls?
Buildings with legacy BMS or no controls typically waste 20-40% of HVAC energy. Modern DDC controllers with weather compensation and adaptive setpoints can achieve payback periods of 2-5 years depending on building size and current energy spend.
Can a BMS help us meet our carbon reduction targets?
Yes. A well-configured BMS reduces energy consumption and carbon emissions by eliminating wasteful operation and optimising plant efficiency. Alpha Controls helps clients quantify savings and provides reporting data for carbon disclosure programmes.
What should be included in a BMS scope of work when tendering with subcontractors?
A clear BMS scope should cover: points schedule with all field devices, control strategy descriptions for every HVAC system, software platform and supervisor requirements, integration requirements (fire alarm, metering, access control), commissioning and witness testing obligations, O&M documentation and training, and warranty terms. Vague scopes are the single biggest cause of BMS change orders. Alpha Controls provides detailed tender returns and can help M&E contractors or consultants tighten their specifications before going to market.
What certifications should a BMS subcontractor have?
At minimum, look for SafeContractor or CHAS accreditation, NICEIC or ECA membership for electrical work, and manufacturer certification on the specified platform (e.g., Trend, Honeywell, Distech). BCIA membership indicates commitment to industry standards. Ask for specific engineer CVs showing platform experience, not just company accreditations. Alpha Controls holds SafeContractor, BCIA, ConstructionLine Gold, and Trend and Distech certifications.
How do you handle scope overlap between BMS and HVAC balancing contractors on site?
This is one of the most common sources of delay and dispute on M&E projects. The BMS contractor needs the HVAC system balanced and setpoints confirmed before control sequences can be optimised. Clear responsibility matrices in the subcontract documents — specifying who provides test points, who witnesses commissioning, and who signs off the air and water balance report — prevent most disputes. Alpha Controls works regularly alongside TAB contractors and can advise on coordination programmes for complex multi-contractor sites.
Can a Trend BMS interface with sensors or actuators from other manufacturers?
Yes. Trend controllers support BACnet, Modbus, and LON protocols, meaning they can communicate with compliant field devices from any manufacturer. This is important for projects where the BMS contractor and the HVAC equipment supplier are different companies. Alpha Controls regularly integrates Trend, Honeywell, and Distech head-end systems with third-party AHUs, chillers, FCUs, and metering devices using open protocols.
What is a realistic programme for BMS commissioning on a new-build commercial project?
BMS commissioning is typically the last trade on a new build, which means programme delays upstream always compress the controls timeline. A realistic commissioning programme for a medium-sized commercial building (say 5,000-10,000m² with AHUs, FCUs, and chiller plant) is 4-8 weeks of active commissioning, followed by 2-4 weeks of seasonal and optimisation adjustments. Alpha Controls provides detailed commissioning programmes at tender stage and flagging realistic milestones to avoid being asked to commission a system that isn't mechanically complete.
Ready to Start Your BMS Project?
Get in touch today for a free consultation and quote. Our expert team is ready to discuss your requirements and provide a tailored solution for your building.









