London Metropolitan University (LMU) – Multiple Campuses

Alpha Controls installed new energy metering across multiple electrical panels and buildings at London Metropolitan University. MID-approved multifunction meters were fitted across main switchboards and sub-distribution panels, and every meter was connected to the central BMS — giving the estates team consumption tracking, alarms, and reporting across the campus from a single point.

London, UK
2025
Educational Facilities
Aerial view of the London Metropolitan University campus, London

Project Overview

London Metropolitan University needed proper visibility of where energy was being consumed across its buildings. Alpha Controls delivered a campus-wide metering installation: new three-phase multifunction meters fitted across multiple electrical panels — from main LV switchboards down to sub-distribution boards — in buildings across the campus.

Every meter was connected back to the central BMS, turning a collection of isolated panels into a single monitored energy network. Consumption is now tracked per panel and per building, with alarms and reporting handled through the BMS rather than manual meter reads.

Project Scope

Alpha Controls supplied and installed Eastron SMART X96-5E three-phase multifunction meters across the campus electrical infrastructure. Meters were mounted on panel doors and within distribution boards — positioned for easy local reading while keeping voltage and current connections made safely inside the panels, with every installation labelled and clearly identified.

With the metering in place, the communications side followed: an RS485 Modbus network was cabled panel to panel, daisy-chaining every meter back to the central BMS head end. Cabling was routed through existing containment where available, with new routes formed — including runs through raised floor voids — to bring panels and buildings across the campus onto the metering network.

System Overview

The installed metering network comprises:

  • Eastron SMART X96-5E multifunction meters — three-phase 230/400V meters with MID approval to EN50470-1/3 Class C, pulse outputs, and RS485 Modbus RTU communications
  • Multiple electrical panels metered — main LV switchboards and sub-distribution boards across multiple campus buildings
  • Door- and panel-mounted installations — meters positioned for local reading, with clean voltage and current terminations inside each panel
  • RS485 Modbus RTU network — every meter daisy-chained back to the central BMS head end
  • New containment routes — including raised floor void runs linking panels and buildings onto the metering network
  • Central BMS integration — consumption tracking, alarms, and reporting functionality across the whole campus

Working on Live Panels

University campuses can't shut down to suit a metering programme. The meters were therefore installed onto live, energised distribution boards, with each panel connection carried out carefully and methodically to keep the electrical infrastructure undisturbed.

Once energised, each meter was verified on site — confirming live voltage and current readings per phase and a running kWh total — before being handed to the BMS integration stage. That panel-by-panel verification meant the network was proven healthy at every point before it was relied upon centrally.

Integration with the Central BMS

The value of sub-metering comes from what you can do with the data. All meters were connected to the central BMS over RS485 Modbus RTU, giving the estates team live consumption tracking for every metered panel and building, alarm functionality on the metering network, and automated reporting from a single supervisory point.

With the metering hierarchy in place, the university can see where energy is being consumed across the campus, spot abnormal usage through BMS alarms, and report on building performance — the foundation for targeting efficiency works and evidencing savings against them.

Results

With the metering network installed, energised and integrated, the campus now has:

  • New energy metering across multiple panels and buildings — MID-approved multifunction meters on main switchboards and sub-distribution boards alike
  • Consumption tracking from the central BMS — per-panel and per-building energy visibility in one place
  • Alarm functionality — the BMS watches the metering network and flags abnormal conditions
  • Automated reporting — energy data reported from the BMS, replacing manual meter reads
  • Delivered on live panels — meters installed, energised and verified across the operating campus

Technical Specifications

Energy Metering

  • Eastron SMART X96-5E Multifunction Meters
  • Three-Phase 3x230/400V AC
  • MID Approved — EN50470-1/3 Class C
  • Pulse Outputs

Communications

  • RS485 Modbus RTU Network
  • Panel-to-Panel Daisy Chain
  • Central BMS Head End
  • Consumption, Alarms & Reporting

Installation

  • Main LV Switchboards & Sub-Distribution Boards
  • Door- & Panel-Mounted Meters
  • New Containment incl. Raised Floor Routes
  • Live Panel Works

Project Delivery

  • Multiple Campus Buildings
  • Educational Facilities Sector
  • Installed, Energised & Verified
  • Central BMS Integration

Need Energy Metering Across Your Estate?

Alpha Controls installs MID-approved energy metering and integrates it into your BMS for consumption tracking, alarms and reporting — across single buildings or multi-building campuses across London and the South East.