Room Pressure Control and Differential Pressure Monitoring

Alpha Controls installs, wires, integrates and commissions room pressure and differential pressure monitoring as part of a building management system, for laboratories, controlled rooms and other spaces across London, Kent and the South East.

What We Do

Our scope covers the installation and wiring of room-pressure and differential-pressure sensors, and of pressure monitors and controllers where these fall within our controls package. We integrate those devices into the BMS — including BACnet integration where applicable, and other supported controls and BMS protocols where appropriate — and we configure the BMS points, alarms, trends and graphics that make the readings usable.

Where the control strategy sits within the agreed controls scope, we write and commission the control logic, and we integrate pressure control with plant and ventilation control strategies where that interface is properly defined within our BMS scope. We commission and test the BMS-side operation of the installed system.

This applies to laboratories, controlled rooms and other spaces where differential pressure must be monitored or controlled. Most of this work reaches us as part of a wider controls package — see our BMS installers London page for how those projects are delivered.

The BMS Scope

What the controls package covers on a room pressure or differential pressure system.

Sensor & Controller Installation
Installation and wiring of room-pressure and differential-pressure sensors, and of pressure monitors and controllers where these fall within our controls package. Cable routes, terminations and power are installed as part of the controls scope.
BMS Integration
Integration of pressure sensors, monitors and controllers into the building management system, including BACnet integration where applicable and other supported controls and BMS protocols where appropriate.
Points, Alarms & Trends
Configuration of the BMS points, alarm thresholds and trend logs that turn a pressure reading into something a facilities team can actually act on, rather than a number nobody sees.
Graphics
Pressure values, alarm states and trend history presented on the BMS graphics alongside the rest of the plant, so a differential-pressure alarm is read in the context of the system that caused it.
Control Logic
Where the control strategy sits within the agreed controls scope, we write and commission the control logic, and integrate pressure control with plant and ventilation control strategies where that interface is properly defined within our BMS scope.
Commissioning & Testing
Commissioning and testing of the BMS-side operation of the installed system — sensor readings proven against the commissioning record, alarms proven to raise, and trends proven to log.

What Sits Outside Our Scope

We work to a specified pressure regime — we do not independently define it. The required pressure differentials, air change rates and containment strategy come from the project's mechanical designer or specialist consultant.

Alpha Controls does not design specialist containment strategies, certify or validate cleanrooms or cleanroom classifications, provide medical, process or laboratory compliance certification, or take responsibility for specialist mechanical design.

Saying so plainly is deliberate. Pressure work attracts enquiries that assume a validation scope, and it is better to be clear about the boundary at the enquiry stage than at handover.

Frequently Asked Questions

Common questions about room pressure and differential pressure monitoring on a BMS.

What does Alpha Controls do on a room pressure system?

We install and wire room-pressure and differential-pressure sensors, and pressure monitors and controllers where these fall within our controls package. We integrate those devices into the BMS, configure the points, alarms, trends and graphics, and commission and test the BMS-side operation. Where the control strategy sits within the agreed controls scope, we write and commission the control logic.

Do you define the pressure regime?

No. We work to a specified pressure regime — we do not independently define it. The required pressure differentials, air change rates and containment strategy come from the project's mechanical designer or specialist consultant. Our scope begins once that regime is specified.

Can room pressure be monitored over BACnet?

Yes, where the sensors, monitors or controllers support it. Pressure values, setpoints and alarm states can be exposed as BACnet objects and read by the BMS alongside the rest of the plant, which is what allows a pressure alarm to be trended and investigated rather than simply annunciated locally. We also work with other supported controls and BMS protocols where appropriate.

Do you certify or validate cleanrooms?

No. Alpha Controls does not design specialist containment strategies, certify or validate cleanrooms or cleanroom classifications, provide medical, process or laboratory compliance certification, or take responsibility for specialist mechanical design. Those sit with the specialist designer, validation contractor or certifying body.

Where does this apply?

Laboratories, controlled rooms and other spaces where differential pressure must be monitored or controlled, in commercial buildings across London, Kent and the South East.

Need Room Pressure Monitoring Integrated Into Your BMS?

Tell us the specified pressure regime and we will scope the sensors, integration, alarms and commissioning around it.