Blog & Insights
Building Management Insights
Expert advice, industry insights, and practical guides on building management systems, energy efficiency, and building automation technology.
Filter & sort
Current sort: Date: Newest first. Read filter: any.
149 articles found

HVAC SystemsFeatured
Why the Frost Stat Is on the Extract Side of a Plate Heat Exchanger
On a plate heat exchanger AHU the frost protection reads the extract, not the incoming fresh air, and engineers rewire it believing it to be a mistake. Why the ice forms on the extract side, how pack frost protection differs from the coil frost stat, and what actually triggers a defrost.
11 Oct 20269 min read
Read Article
Latest Articles

HVAC Systems
What Is a Recuperator AHU, and How Does It Compare With a Thermal Wheel?
A recuperator AHU recovers heat through a static plate pack; a thermal wheel does the same job with a rotating matrix and moves moisture with it. What separates them, the efficiency figures the manufacturers actually publish, and the different point schedule each type lands on a controls contractor.
11 Oct 20269 min
Read
BMS Technical
AHU Controls: How Air Handling Unit Control Sequences Actually Work
A full guide to AHU control sequences: start/stop and optimum start, the damper sequence, fan control, coil sequencing through a deadband, CO₂ demand ventilation, heat recovery by device type, both frost protections, and what to prove at commissioning before you accept a unit.
11 Oct 202612 min
Read
Case Studies
24V Window Actuator Wiring After a School Roof Replacement
Royal Harbour Academy, Ramsgate: eight weather-damaged 24V window actuator feeds re-cabled in 4 mm² fire-resistant cable, AHU control cabling drawn back and re-terminated, and extract fans wired back to the BMS during a roof replacement.
2 Oct 20267 min
Read
HVAC Systems
VAV Installation: TROX VAVs & Sontay CO₂ on a Trend BMS
A real VAV installation on a refurbished office floor: four TROX TA-Silenzio extract VAVs and Sontay duct CO₂ sensors wired back to a Trend panel two floors up. Core-by-core terminations, the signal-range and mode checks that decide whether the floor works, and what good looks like at handover.
28 Sept 20269 min
ReadMore Articles
Page 2 of 15

BMS Technical7 Sept 202611 min
Three-Phase Motor Wiring: Star, Delta and Six-Terminal Connections Explained
Read Article
BMS Technical7 Sept 202613 min
AHU Fan VSD Tripping? A Practical Motor and Drive Fault-Finding Guide
Read Article
BMS Technical25 Aug 202612 min
ABB ACH580 Fault 3381: Tracing an Output Phase Loss to Incorrect Motor Connections
Read Article
Water & Utilities22 Aug 202611 min
Cold Water Tank Level Sensors: What They Do, When You Need Them, and What Retrofitting One Actually Involves
Read Article
BMS Technical11 Aug 202613 min
Open Protocol BMS Systems: How They Work, Pros and Cons
Read Article
BMS Technical11 Aug 202614 min
BMS Field Devices: The Complete Field Equipment List
Read Article
Tendering / Quoting30 Jul 202618 min
The BMS Tender Process: A Step-by-Step Timeline From Enquiry to Submission
Read Article
Tendering / Quoting30 Jul 202615 min
How to Handle RFIs During a BMS Tender (And Why Sloppy Logging Costs You Later)
Read Article
Tendering / Quoting30 Jul 202613 min
BMS Lead Times and London Delivery Risks: What a Tender Price Must Account For
Read Article
Tendering / Quoting22 Jul 20269 min
BMS Cost Per Point: The Quantity Surveyor's Guide to Pricing Trend & Distech Controls Packages