Blog & Insights
Building Management Insights
Expert advice, industry insights, and practical guides on building management systems, energy efficiency, and building automation technology.
Filter & sort
Current sort: Date: Newest first. Read filter: any.
149 articles found

HVAC SystemsFeatured
Why the Frost Stat Is on the Extract Side of a Plate Heat Exchanger
On a plate heat exchanger AHU the frost protection reads the extract, not the incoming fresh air, and engineers rewire it believing it to be a mistake. Why the ice forms on the extract side, how pack frost protection differs from the coil frost stat, and what actually triggers a defrost.
11 Oct 20269 min read
Read Article
Latest Articles

HVAC Systems
What Is a Recuperator AHU, and How Does It Compare With a Thermal Wheel?
A recuperator AHU recovers heat through a static plate pack; a thermal wheel does the same job with a rotating matrix and moves moisture with it. What separates them, the efficiency figures the manufacturers actually publish, and the different point schedule each type lands on a controls contractor.
11 Oct 20269 min
Read
BMS Technical
AHU Controls: How Air Handling Unit Control Sequences Actually Work
A full guide to AHU control sequences: start/stop and optimum start, the damper sequence, fan control, coil sequencing through a deadband, CO₂ demand ventilation, heat recovery by device type, both frost protections, and what to prove at commissioning before you accept a unit.
11 Oct 202612 min
Read
Case Studies
24V Window Actuator Wiring After a School Roof Replacement
Royal Harbour Academy, Ramsgate: eight weather-damaged 24V window actuator feeds re-cabled in 4 mm² fire-resistant cable, AHU control cabling drawn back and re-terminated, and extract fans wired back to the BMS during a roof replacement.
2 Oct 20267 min
Read
HVAC Systems
VAV Installation: TROX VAVs & Sontay CO₂ on a Trend BMS
A real VAV installation on a refurbished office floor: four TROX TA-Silenzio extract VAVs and Sontay duct CO₂ sensors wired back to a Trend panel two floors up. Core-by-core terminations, the signal-range and mode checks that decide whether the floor works, and what good looks like at handover.
28 Sept 20269 min
ReadMore Articles
Page 11 of 15

BMS Technical22 Apr 20269 min
Siemens Desigo CC vs Honeywell EBI
Read Article
BMS Technical22 Apr 202612 min
Distech ECLYPSE vs Trend IQ: Is BACnet Enough to Make Them Talk?
Read Article
BMS Technical22 Apr 20268 min
Inheriting a Distech BMS: What FM Managers Actually Find
Read Article
BMS Technical22 Apr 202610 min
Trend IQ4 vs Distech ECLYPSE: 2026 Specification Guide
Read Article
BMS Technical22 Apr 20267 min
Siemens Desigo CC: More Data Than You Know What to Do With
Read Article
BMS Technical22 Apr 20269 min
Schneider EcoStruxure in Multi-Tenant Buildings
Read Article
Fire & Life Safety20 Apr 202616 min
Fire Damper Testing UK: Who Is Responsible, What Compliance Looks Like, and How BMS Integration Changes Everything
Read Article
BMS Upgrades17 Apr 202618 min
School BMS Upgrade: Costs, Funding, Timelines, and What Your School Actually Needs
Read Article
Energy Management13 Apr 202614 min
MEES 2027 Update: The Dropped EPC C Milestone — and What BMS Controls Still Do for Your Rating
Read Article
BMS Upgrades8 Apr 202618 min
University BMS Upgrade During Summer: Why the Six-Week Window Decides Your Energy Future
Read ArticleReady to Optimise Your Building?